New 2-channel 5V relay module with optocoupler isolation supports high and low level triggering of 5V
2-channel 5V relay module with optocoupler isolation
Product Introduction
One module description:
1. The module adopts genuine high-quality relays, with normally open interface load: AC 250V/10A, DC 30V/10A;
2. Adopting patch optocoupler isolation, with strong driving capability and stable performance; Trigger current 5mA;
3. The working voltage of the module is available in 5V, 9V, 12V, and 24V options;
4. The module can be triggered by setting high or low levels through jumper wires;
5. Fault tolerant design, even if the control line is broken, the relay will not operate;
6. Power indicator light (green), relay status indicator light (red)
7. The interface design is user-friendly, and all interfaces can be directly wired out through terminal blocks, which is very convenient
8. Module size: 50mm * 41mm * 18.5mm (length * width * height)
9. There are 4 fixed bolt holes with a diameter of 3.1mm and a spacing of 44.5mm * 35.5mm
Two module interface:
1 DC+: Connect the positive pole of the power supply (voltage according to relay requirements, with options of 5V, 9V, 12V, and 24V)
2 DC-: Connect the negative pole of the power supply
3 IN1: One signal trigger terminal, which can be set to high or low level to control the relay to close
3 IN2: 2-channel signal trigger terminal, can set high or low level control relay to close
Relay output terminal:
1 NO1: 1 relay normally open interface, suspended before closing the relay, short circuited to COM1 after closing
2 COM1: 1 relay common interface
3 NC1: 1 relay normally closed interface, short circuited to COM1 before relay closing, suspended after closing
4 NO2: 2-channel relay normally open interface, with the relay suspended before closing and short circuited to COM2 after closing
5 COM2: 2-channel relay common interface
6 NC2: 2-channel relay normally closed interface, short circuited to COM2 before relay closing, suspended after closing
Technical parameters
Relay version |
Static current | Maximum current | Trigger current | Trigger voltage (low) | High |
5V |
5mA | 190mA | 2-4mA | 0-1.5V | 2.5-5V |
12V | 5mA | 80mA | 2-4mA | 0-4V | 4.5-12V |
24V | 5mA | 50mA | 2-4mA | 0-8V | 8.5-24V |
High and low level trigger selection terminal:
1. S1 is the high and low level trigger selection for one relay;
2. S2 is the high and low level trigger selection for 2-channel relays;
3. When com is short circuited to low, the corresponding relay is triggered at a low level, and when com is short circuited to high, it is triggered at a high level
Product Function
Product Show
Payment&Transportation
Official Certificate&Certificate
Multiple product supply
Company office environment
Warehouse Real Shot
Standard packaging
We also provide :
Part No | Manufacturer | Date Code | Quantity | Description |
LM22676ADJ | NS | 19+ | 250 | SOP8 |
TPS562201DDCR | TI | 22+ | 795500 | SOT23-6 |
NJG1806K75 | JRC | 22+ | 500000 | DFN6 |
TLV74318PDQNR | TI | 22+ | 402000 | X2SON-4 |
NJG1801K75 | JRC | 22+ | 300000 | SMD |
NJG1804K64 | JRC | 22+ | 300000 | DFN8 |
LM27761DSGR | TI | 22+ | 151000 | WSON8 |
TLV62565DBVR | TI | 22+ | 138000 | SOT23-5 |
TPS613222ADBVR | TI | 22+ | 108000 | SOT23-5 |
LNK625DG-TL | POWER | 22+ | 100000 | SOP-8 |
OPA4322AIPWR | TI | 22+ | 100000 | TSSOP14 |
TLV75528PDRVR | TI | 22+ | 99000 | WSON-6 |
TPS7A2025PDQNR | TI | 22+ | 78500 | X2SON-4 |
TLV62568DBVR | TI | 22+ | 72000 | SOT23-5 |
STM32L051K8U6TR | ST | 22+ | 60000 | QFN32 |
SKY66421-11 | SKYWORKS | 22+ | 56500 | QFN16 |
TPS7A1111PDRVR | TI | 22+ | 54000 | WSON6 |
TLV62569PDDCR | TI | 22+ | 52000 | SOT23-6 |
TLV62569DBVR | TI | 22+ | 48000 | SOT23-5 |
TPS23753APWR | TI | 22+ | 40000 | TSSOP14 |
NB691GG-Z | MPS | 22+ | 30000 | QFN |
SN74AHC1G02DBVR | TI | 22+ | 27939 | SOT-23 |
TPS63000DRCR | TI | 22+ | 23238 | VSON10 |
TLV75533PDRVR | TI | 22+ | 21500 | WSON6 |
NB687BGQ-Z | MPS |