Image shown is a representation only.

Exact specifications should be obtained from the product data sheet.

XY-L30A battery charging control module digital full charge power-off overcharge protection switch 6-60V

Manufacturer Product Number
XY-L30A
Description

XY-L30A battery charging control module

Package Condition
Bulk

Module highlights

1. Any battery, including lithium batteries, can be used with a voltage of 6-60V;

2. LCD display, with clear visibility of battery voltage, charging percentage, and charging time;

3. The function is very powerful, it can automatically control the charging, control the charging time, and set and upload corresponding parameters through the serial port;

Product Function

详情-02

1、 Function Description

1. Automatic charging control function:

By setting the upper limit voltage UP and lower limit voltage dn; When the battery voltage is ≤ the lower limit voltage dn, the relay conducts and the charger starts charging the battery; When the battery voltage is greater than or equal to the upper limit voltage UP, the relay will disconnect and complete an automatic charging process;

2. Charging time control function:

How to activate the time control function?

After entering the parameter settings, if the parameter OP is not set to 0, the time control function will be enabled. The default parameters for OP are: --:-- h, Default time control function is not enabled;

After enabling the time control function (OP is not 0), when the battery voltage is less than the lower limit voltage dn, the charger starts charging the battery and the system starts timing; During the timing period, if the battery voltage is greater than or equal to the upper limit voltage UP, the relay will disconnect; If the battery voltage is less than the upper limit voltage, but the charging time OP has expired, the relay will disconnect; If the OP time is up and the battery voltage is still below the lower limit voltage dn, the relay will remain conductive, automatically turn off the charging time control function, and flash to display H: ER to remind the user that the time parameter setting is unreasonable; Press any key to stop flashing;

Note: Time format: 00:59 (00 represents hours, 59 represents minutes) The longest time is 99:59, which is 100 hours.

3. Serial port data upload and parameter setting function:

The system supports UART data upload and parameter setting function (TTL level);

UART:115200,8,1

 命令
Command
功能
Function
On 继电器使能打开
Relay enables opening
Off 继电器使能关闭
Relay enables closing
Start 启动数据上报功能
Activate data reporting function
Stop 停止数据上报功能
Stop data reporting function
Read 获取系统的参数
Obtain system parameters
Dw10.0 设置下限电压
Set lower limit voltage
Up20.0 设置上线电压
Set the online voltage
XX:XX 设置充电时间,00:00关闭充电时间控制功能
Set charging time, turn off charging time control function at 00:00

Data upload message format:

Battery voltage+battery percentage+charging time+charging status

12.0V,020%,00:10, OP

详情-03

2、 Parameter settings

a) Press and hold the SET button to enter the parameter setting interface, and the LCD will display SET;

b) After entering the parameter setting interface, short press the SET key to switch the set parameters;

c) After selecting the parameters, they can be set through the UP/DOWN keys, supporting short and long presses (quick increase or decrease);

d) To set other parameters, repeat steps b) c);

e) After all parameter settings are completed, long press the SET key to exit and save;

3、 Key Function Description

In the operating interface (main interface),

Short press the SET button to display the currently set parameters;

Short press the UP button to switch between displaying charging percentage and charging time;

Short press the DOWN button to select on/off relay enable. If the relay enable is turned off, 'OFF' will be displayed as a reminder and the relay will disconnect;

Long press the UP button to set the state of the LCD backlight (L-P), OFF: the backlight stays on, on: The backlight will automatically turn off after 5-10 minutes;

Press and hold the SET button to enter parameter settings.

4、 Calculation of voltage percentage: battery voltage divided by (upper limit voltage - lower limit voltage).

5、 Additional features

a) Charging time recording function: When the charging time control is not turned on, the product will record the complete time once. When entering the time display interface, the charging time will flash; Clear when exiting the time display interface again or when the next charging is turned on (relay conducting);

b) Parameter automatic detection: After setting the parameters and exiting, if the lower voltage limit dn is greater than or equal to the upper voltage limit up, the system will flash and display "ERR" as a reminder;

c) Battery connection detection: This product is attached to the battery. If the battery is not connected, the system will display "nbE" in the downstream as a reminder;

 

Matters needing attention

6、 Common Fault Analysis

Q: How many V levels are suitable for use? How many volts is this module suitable for?

Answer: This model is suitable for use within the voltage range of a minimum of 6V and a maximum of 60V. The maximum expenditure level is 48V, as a fully charged 48V battery will burn out at around 60V. If your battery is higher than 48V, please choose another model.

Q: The relay makes a popping sound after being powered on! Is the indicator light flashing?

Answer: This is because your charging current is too high or the battery capacity is too small, causing it to immediately reach the upper voltage limit when powered on. The relay is disconnected, and after disconnection, the voltage quickly drops to the lower voltage limit and starts charging again, repeating the cycle. At this time, you need to reduce the charging current, which is usually 1 to 1.5 times the battery capacity. For example, the charging current of a 20AH battery is generally around 2-3A! Attention, high current charging can cause the battery to heat up, accelerate aging, swell, and even explode!

Question: What control method? Can it automatically cycle charging? Can I charge while using it? Can the flow be limited?

Answer: This is voltage control, for example, setting a lower voltage limit of 12.0V and an upper voltage limit of 14.5V. When the voltage reaches 14.5V, the power will be cut off, and when the voltage drops to 12.0V, the relay will close and start charging again; You can charge while using it, and the voltage control mode only functions as turning off and on, without current limiting. The charging current depends entirely on your charger!

Q: Can a 12V input charge a 24V battery, or can a 48V input charge a 12V battery?

Answer: This is a simple voltage controller that only functions as a switch and cannot transform voltage to charge the battery. Therefore, you need to prepare a charger for the type of battery you want to charge! necessary!

Product Show

主图-00

主图-01

主图-04

Payment&Transportation

详情8.1

Official Certificate&Certificate

详情页3.1

Multiple product supply

详情5.1

Company office environment

详情6.1

Warehouse Real Shot

170019007688325e.png

Standard packaging

详情9

We also provide :

Part No Manufacturer Date Code Quantity Description
LM22676ADJ NS 19+ 250 SOP8
TPS562201DDCR TI 22+ 795500 SOT23-6
NJG1806K75 JRC 22+ 500000 DFN6
TLV74318PDQNR TI 22+ 402000 X2SON-4
NJG1801K75 JRC 22+ 300000 SMD
NJG1804K64 JRC 22+ 300000 DFN8
LM27761DSGR TI 22+ 151000 WSON8
TLV62565DBVR TI 22+ 138000 SOT23-5
TPS613222ADBVR TI 22+ 108000 SOT23-5
LNK625DG-TL POWER 22+ 100000 SOP-8
OPA4322AIPWR TI 22+ 100000 TSSOP14
TLV75528PDRVR TI 22+ 99000 WSON-6
TPS7A2025PDQNR TI 22+ 78500 X2SON-4
TLV62568DBVR TI 22+ 72000 SOT23-5
STM32L051K8U6TR ST 22+ 60000 QFN32
SKY66421-11 SKYWORKS 22+ 56500 QFN16
TPS7A1111PDRVR TI 22+ 54000 WSON6
TLV62569PDDCR TI 22+ 52000 SOT23-6
TLV62569DBVR TI 22+ 48000 SOT23-5
TPS23753APWR TI 22+ 40000 TSSOP14
NB691GG-Z MPS 22+ 30000 QFN
SN74AHC1G02DBVR TI 22+ 27939 SOT-23
TPS63000DRCR TI 22+ 23238 VSON10
TLV75533PDRVR TI 22+ 21500 WSON6
NB687BGQ-Z MPS

Write your review

XY-L30A battery charging control module digital full charge power-off overcharge protection switch 6-60V

XY-L30A battery charging control module

Write your review

Other Products In The same category:

2000In stock:
Can ship immediately
QUANTITY
All prices are in USD

SEND
RFQ