Relay module delay power-off disconnection triggering delay cycle timing circuit switch XY-LJ02

Manufacturer Product Number
XY-LJ02
Description

Relay module delay power-off disconnection triggering delay cycle

Package Condition
Bulk

Product parameters

1: Working voltage: 6-30V, supports MICRO USB 5.0V power supply

2: Trigger signal source: high-level trigger (3.0V~24V), low-level trigger (0.0V~0.2V), switch quantity control (passive switch).

3: Output capability: Can control devices within 30V5A DC or 220V5A AC

4: Static current: 15MA Working current: 50mA

5: Service life: over 100000 cycles; Working temperature: -40-85 ° C; Size: 8.0 * 3.8 * 1.9CM

6. Equipped with optocoupler isolation to enhance anti-interference ability, industrial grade circuit board, set parameters to be permanently remembered after power failure.

Product highlights

1. Equipped with LCD display, the current mode and parameters are clear at a glance, very clear, simple and practical;

2. Supports high and low level triggering, controlled by switches, suitable for most occasions;

3. Wide voltage power supply (6-30V) supports micro USB 5.0V power supply, making it very convenient to use;

4. Support UART data upload and parameter settings;

5. It has a one button emergency stop function (STOP button), with reverse connection protection, and reverse connection does not burn out;

6. Added sleep mode, which automatically turns off the LCD backlight within 5 minutes without any operation after enabling it; Wake up with any button;

7. Different OP, CL, and LOP parameters can be set, which are independent of each other and saved separately;

8. All setting parameters will be automatically powered off and saved.

Product Use

Circuit construction

1. Prepare accessories, DC power supply, several wires, and control equipment needed

未标题-1

2. Circuit connection

The following diagram shows the connection of weak current to strong current. The working voltage can be supplied by Micro UsB5V or by terminals 6-30V

详情-09

The following diagram shows the connection of the control equipment and module working voltage sharing the same power supply, ensuring that the power supply voltage is between 6V~30V

详情-10

Working mode:

P1: After the signal is triggered, the relay conducts for OP time and then disconnects; During the OP time, the signal is triggered again and becomes invalid;

P2: After the signal is triggered, the relay conducts for OP time and then disconnects; During the OP time, the signal triggers a new timer again;

P3: After the signal is triggered, the relay conducts for OP time and then disconnects; During the OP time, the signal triggers a reset again, the relay disconnects, and the timing stops;

P4: Give the trigger signal, after the relay disconnects the CL time, the relay conducts the OP time, and the timer is complete, After completion, disconnect the relay;

P5: Give the trigger signal, after the relay conducts OP time, the relay disconnects CL time, and then cycles the above actions. Within the cycle, give the signal again, the relay disconnects, and the timer stops; The number of loops (LOP) can be set;

P6: After power on, there is no need to trigger a signal. The relay conducts OP time and disconnects CL time, and the above actions are repeated; The number of loops (LOP) can be set;

P7: If there is a trigger signal for the signal holding function, the timer will be reset and the relay will remain conductive; When the signal disappears, disconnect the relay after timing OP; During the timing period, if there is a signal again, the timing will be reset to zero;

Product Timing range

0.01 seconds (minimum)~9999 minutes (maximum) continuously adjustable

How to choose a timing range:

In the OP/CL parameter modification interface, short press the STOP button to select the timing range;

XXXX has no decimal point, with a timing range of 1 second to 9999 seconds

XXX. The decimal point of X is in ten places, with a timing range of 0.1 seconds to 999.9 seconds

XX. XX decimal point in hundreds, timing range 0.01 seconds~99.99 seconds

X. X.X.X decimal point fully lit, timing range 1 minute to 9999 minutes

For example, if you want to set the OP to 3.2 seconds, move the decimal point to ten and the LCD will display 003.2

Parameter description: OP conduction time, CL disconnection time, LOP cycle times (1-9999 times, "----" represents Infinite loops)

Product Parameter settings

a) Press and hold the SET key to enter the settings interface;

b) Firstly, set the working mode, which flashes as a reminder. Set the working mode by short pressing the UP/DOWN keys;

c) Short press the SET button to select the working mode and enter the system parameter settings;

d) In the system parameter setting interface, short press the SET key to switch the system parameters to be modified, and short/long press the UP/DOWN keys to modify them;

(Note: Short press SET is invalid in P-1~P3, P-7 modes):

e) In the OP/CL parameter modification interface, short press STOP to switch the timing unit (1s/0.1s/0.01s/1min);

f) All parameter settings are completed. Long press the SET key to save the parameter settings and exit the settings interface,

4 Remote data upload and parameter setting function

The system supports UART data upload and parameter setting function (TTL level);

UART:9600,8,1

命令
Command
功能
Function
read 读取系统参数
Read system parameters
op:xxxx 1s
op:xxx.x 0.1s
op:xx.xx 0.01s
op:x.x.x.x 1 min
Cl:xxxx 1s
Cl:xxx.x 0.1s
Cl:xx.xx 0.01s
Cl:x.x.x.x 1 min
LP:xxxx 循环次数
Number of cycles
ON 开启继电器功能
Activate relay function
OFF 关闭继电器功能
Turn off the relay function
PX 设置模式P1,P2等
Set modes P1, P2, etc

Additional features

a) Automatic sleep function: In the running interface, long press the STOP button to turn on or off the automatic sleep function (L-P selection on will activate the sleep function, off will deactivate the sleep function);

b) Relay function selection: In the operation interface, short press the STOP button to activate or deactivate the relay function The relay is conducting normally when the conduction condition is met OFF 'The relay does not conduct even if it meets the conduction condition:' In the OFF state, the system flashes and displays' OUT ';

c) Parameter viewing: In the running interface, short press the SET button to display the current parameter settings of the system, which does not affect the normal operation of the system;

d) Display content switching: In the P5 P-6 mode, short press the DOWN key to switch the display content (running time/number of cycles);

Product Size

详情-11

Product Show

主图-00

主图-02

主图-03

主图-04

Payment&Transportation

详情8.1

Official Certificate&Certificate

详情页3.1

Multiple product supply

详情5.1

Company office environment

详情6.1

Warehouse Real Shot

170019007688325e.png

Standard packaging

详情9

We also provide :

Part No Manufacturer Date Code Quantity Description
LM22676ADJ NS 19+ 250 SOP8
TPS562201DDCR TI 22+ 795500 SOT23-6
NJG1806K75 JRC 22+ 500000 DFN6
TLV74318PDQNR TI 22+ 402000 X2SON-4
NJG1801K75 JRC 22+ 300000 SMD
NJG1804K64 JRC 22+ 300000 DFN8
LM27761DSGR TI 22+ 151000 WSON8
TLV62565DBVR TI 22+ 138000 SOT23-5
TPS613222ADBVR TI 22+ 108000 SOT23-5
LNK625DG-TL POWER 22+ 100000 SOP-8
OPA4322AIPWR TI 22+ 100000 TSSOP14
TLV75528PDRVR TI 22+ 99000 WSON-6
TPS7A2025PDQNR TI 22+ 78500 X2SON-4
TLV62568DBVR TI 22+ 72000 SOT23-5
STM32L051K8U6TR ST 22+ 60000 QFN32
SKY66421-11 SKYWORKS 22+ 56500 QFN16
TPS7A1111PDRVR TI 22+ 54000 WSON6
TLV62569PDDCR TI 22+ 52000 SOT23-6
TLV62569DBVR TI 22+ 48000 SOT23-5
TPS23753APWR TI 22+ 40000 TSSOP14
NB691GG-Z MPS 22+ 30000 QFN
SN74AHC1G02DBVR TI 22+ 27939 SOT-23
TPS63000DRCR TI 22+ 23238 VSON10
TLV75533PDRVR TI 22+ 21500 WSON6
NB687BGQ-Z MPS

Write your review

Relay module delay power-off disconnection triggering delay cycle timing circuit switch XY-LJ02

Relay module delay power-off disconnection triggering delay cycle

Write your review

Other Products In The same category:

50000In stock:
Can ship immediately
QUANTITY
All prices are in USD

SEND
RFQ