Image shown is a representation only.
Exact specifications should be obtained from the product data sheet.
Temperature controller STC-1000 aquarium hatching seafood machine electronic digital display microcomputer controller switch
Temperature controller STC-1000 electronic digital display microcomputer
Module Parameter
Product Name: Digital Microcomputer Temperature Controller
Product Name: STC-1000
Measurement range:- 50℃~99℃
Measurement accuracy: ± 1 ℃ (-50 ℃~70 ℃)
Resolution: 0.1 ℃
Whole machine power consumption: less than 3W
Sensor: NTC sensor (1 meter)
Environmental temperature: 0~60 ℃
Relative humidity: 20-85% (no condensation)
Overall dimensions: 75 * 34.5 * 85MM
Installation opening: 71 * 29mm
Shell material: ABS flame retardant plastic shell
Output Capacity: Refrigeration (10A/250VAC) Heating (10A/250VAC)
Product Features
Indicator light status description:
指示灯 Indicator light |
功能 Function |
备注 Remarks |
Cool指示灯 Cool indicator light |
亮:制冷工作;灭:制冷关闭;闪烁:压机延时 Bright: cooling work; Extinguish: Cooling is turned off; Flashing: Press delay |
Cool、Heat两指示不能同时亮 Cool and Heat indicators cannot light up simultaneously |
Heat指示灯 Heat indicator light |
亮:加热工作;灭:加热关闭 Bright: Heating operation; Extinguish: Heating off |
|
Set指示灯 Set indicator light |
亮:参数设置状态 Bright: Parameter setting status |
Menu Description:
菜单标识 Menu identification |
菜单功能 Menu function |
设定范围 Set Range |
出厂设定 Factory |
F1 | 温度设定值 Temperature setting value |
-50.0-99.9℃ | 10.0℃ |
F2 | 温差设定值 Temperature difference setting value |
0.3-10.0℃ | 0.5℃ |
F3 | 压机延时 Press delay |
1~10分钟/minute | 3分钟/minute |
F4 | 温度校正 Temperature correction |
-10.0~10.0℃ | 0℃ |
Key operation instructions
1. Method for viewing parameters:
When the controller is working normally, press and immediately release the ▲ key once to display the temperature setting value; Press and immediately release the ▼ key once to display the temperature difference setting value. Return to normal temperature display status after 2 seconds.
2. Parameter setting method:
When the controller is working normally, hold down the "S" key for more than 3 seconds to enter the parameter modification mode. The "Set" indicator light will be on, and the digital display will show the code of a menu item. Press the "▲" or "▼ Save parameter modifications and return to normal display state. If there are no key operations within 10 seconds, the parameter modifications will not be saved and return to normal display state
If there is an error when saving parameters, it will display "Er" for 3 seconds and return to the normal display state.
Power supply: 110-220VAC ± 10%, 50/60Hz (or DC12V/DC24V)
Measurement and control temperature range:- 50℃~+110℃
Resolution: 0.1
Accuracy: ± 1 ℃
Relay output contact capacity: Heating: 10A/240VAC,
Refrigeration: 10A/240VCA
Sensor H-type: Imported NTC sensor, with a wire length of 1 meter
Shell material: gray ABS flame-retardant plastic shell
Net weight 120g Gross weight 140g Press and hold Set for 5 seconds to enter internal parameter settings
Press up and down to switch P0... P8, press Rst to confirm and return
代码 Code |
代码说明 Code Description |
设置范围 Set scope |
出厂设定 Factory setting |
P0 | 制冷模式/加热模式 Cooling mode/Heating mode |
C/H | C |
P1 | 回差设定 Return difference setting |
0.1-30 | 2 |
P2 | 最高设定范围 Maximum setting range |
120 | 120 |
P3 | 最低设定范围 Minimum setting range |
-55 | -55 |
P4 | 温度校正 Temperature correction |
-10.0~+10.0℃ | 0 |
P5 | 延时启动时间 Delay start time |
0-10 分钟/minute | 0 |
P6 | 高温报警 High temperature alarm |
-50~110 | OFF |
P7 | 数据锁开关 Data lock switch |
on/off | OFF |
P8 | 恢复出厂设置 Restore factory settings |
on/off | OFF |
P0 cooling and heating mode
Please set the cooling mode to C when starting at high temperature
Low temperature start for heating mode, please set it to H
P1 hysteresis setting
In heating mode (H): When the measured value is less than or equal to the set value and there is a difference, the output will start heating until the set value is reached and stop
In cooling mode (C): When the measured value is ≥ the set value+hysteresis, start outputting cooling until the set value stops
P2 maximum setting range: The maximum value when setting the temperature does not exceed this value
P3 minimum setting range: When setting the temperature, the minimum value should not be lower than this value
P4 temperature calibration: When there is a difference between the measured temperature and the standard temperature, this function can be used for calibration. The calibrated temperature is equal to the temperature before calibration plus the calibration value
P5 delayed start time unit: minutes. When controlling the compressor equipment for cooling, the delay time can be set as needed. When the controller outputs, the equipment will not start immediately and needs to run the set delay time before starting
P6 high temperature alarm: When the measured value is greater than this value, the screen displays a beep alarm and forcibly disconnects the output
P7 Data Lock Function: Enabling the data lock can keep the current settings unchanged. At this time, setting the temperature and function are invalid. If modification is needed, the data lock function needs to be turned off
P8 factory reset
Long press SET to switch to P8, press SET once to set on, press Rst to restore factory settings
Product Size
Product Show
Payment&Transportation
Official Certificate&Certificate
Multiple product supply
Company office environment
Warehouse Real Shot
Standard packaging
We also provide :
Part No | Manufacturer | Date Code | Quantity | Description |
LM22676ADJ | NS | 19+ | 250 | SOP8 |
TPS562201DDCR | TI | 22+ | 795500 | SOT23-6 |
NJG1806K75 | JRC | 22+ | 500000 | DFN6 |
TLV74318PDQNR | TI | 22+ | 402000 | X2SON-4 |
NJG1801K75 | JRC | 22+ | 300000 | SMD |
NJG1804K64 | JRC | 22+ | 300000 | DFN8 |
LM27761DSGR | TI | 22+ | 151000 | WSON8 |
TLV62565DBVR | TI | 22+ | 138000 | SOT23-5 |
TPS613222ADBVR | TI | 22+ | 108000 | SOT23-5 |
LNK625DG-TL | POWER | 22+ | 100000 | SOP-8 |
OPA4322AIPWR | TI | 22+ | 100000 | TSSOP14 |
TLV75528PDRVR | TI | 22+ | 99000 | WSON-6 |
TPS7A2025PDQNR | TI | 22+ | 78500 | X2SON-4 |
TLV62568DBVR | TI | 22+ | 72000 | SOT23-5 |
STM32L051K8U6TR | ST | 22+ | 60000 | QFN32 |
SKY66421-11 | SKYWORKS | 22+ | 56500 | QFN16 |
TPS7A1111PDRVR | TI | 22+ | 54000 | WSON6 |
TLV62569PDDCR | TI | 22+ | 52000 | SOT23-6 |
TLV62569DBVR | TI | 22+ | 48000 | SOT23-5 |
TPS23753APWR | TI | 22+ | 40000 | TSSOP14 |
NB691GG-Z | MPS | 22+ | 30000 | QFN |
SN74AHC1G02DBVR | TI | 22+ | 27939 | SOT-23 |
TPS63000DRCR | TI | 22+ | 23238 | VSON10 |
TLV75533PDRVR | TI | 22+ | 21500 | WSON6 |
NB687BGQ-Z | MPS |