Free hotline:
86-755-88844016
+852 2632 9637
Image shown is a representation only.
Exact specifications should be obtained from the product data sheet.
XH-W1209 digital precision temperature controller,miniature temperature control board (red and blue light)
XH-W1209 digital precision temperature controller, temperature control switch
Product parameters
Supply voltage: DC12V
Temperature control range:- 55℃~120℃
Temperature control accuracy: 0.1 ℃
Digital tube: The display mode is a three in one digital display
Probe type: NTC10K/B3950, Waterproof probe L=0.5 meters
Output type: Relay output 10A
Product Application scope
Can be used for chassis temperature control, poultry hatching, air conditioning systems, temperature protection, and other occasions.
Product Function Diagram
Instructions
After connecting the wires, the controller will power on and display the current real-time temperature. Short press the SET button and it will flash to set the stop temperature. Then press the SET button again to return to the current real-time temperature. Press and hold the SET button for more than 1 second until "P0" is displayed to enter the mode setting interface. The setting process is as follows: press the+- button to select the mode (P0-P6)>press the SET button to enter the mode setting parameters>press the+- button to select the parameter value>press the SET button to return to the mode setting>press and hold the SET button or wait for 3 seconds for automatic saving and returning to the real-time display temperature interface.
模式设置参照列表 Reference List for Mode Settings |
|||
长按SET键1秒以上进入主菜单设定 Press and hold the SET button for more than 1 second to enter the main menu settings |
|||
代码 Code |
代码说明 Code Description |
设置范围 Set range |
出厂设定 Factory setting |
P0 | 加热/制冷 Heating/Cooling |
H/C | C |
P1 | 回差设定 Return difference setting |
0.1-20 | 2 |
P2 | 最高设置上限 Maximum setting limit |
24~120℃ | 120 |
P3 | 最低设置下限 Minimum setting lower limit |
-55~14℃ | -55 |
P4 | 温度校正 Temperature correction |
-10℃~10℃ | 0 |
P5 | 延时启动时间 Delay start time |
0-10分钟 | 0 |
P6 | 高温报警 High temperature alarm |
0℃-120℃ | OFF |
关机状态下长按+-开机可恢复出厂设置 Long press+- power on while turned off to restore factory settings |
Heating mode:
When the temperature set value return difference is ≤ the temperature measurement value, the relay conducts; When the temperature measurement value is greater than or equal to the temperature setting,When the value is set, the relay is disconnected.
Example: Control the radiator to heat up to 60 ℃ and stop, then cool down to 50 ℃ and start again. Heating mode needs to be set with a temperature difference of 10 degrees, which should be set as follows: When displaying the temperature normally, press SET once to flash the temperature and set the stop temperature value to 60 2. Long press SET to display P0 and set working mode H 3. Set the P1 hysteresis value to 10 |
Cooling mode:
When the temperature setting value+hysteresis value ≥ temperature measurement, the relay is turned on; When the temperature measurement value is ≤ the temperature setting value, the relay will disconnect
Example: Control the refrigerator to cool down to -5 ℃ and stop. When the temperature rises to 0 ℃, start cooling again The cooling mode needs to be set with a hysteresis value of 5 ℃, which should be set as follows: When displaying the temperature normally, press SET once to flash the temperature and set the stop temperature value to -5 2. Long press SET to display P0 and set working mode C 3. Set the P1 hysteresis value to 5 |
P0: Working mode
When using the thermostat for the first time, the mode must be set. If it is used for heating (low temperature start, high temperature stop), it should be set to H; If used for refrigeration (high temperature start, low temperature stop), it should be set to C.
P1: Return difference setting
Long press the SET button to enter the setting mode, select P1, and then press the SET button again to set the hysteresis value. (Return difference refers to the difference required for the controller to resume operation after reaching the set temperature, for example: when set to heating mode, heating to 40 ℃, stopping at 35 ℃, and starting again, the return difference is 5).
P2/P3: Limit setting value (non temperature controlled)
P2 limits the maximum set value (non temperature controlled), P3 limits the minimum set value (non temperature controlled) with a minimum distance of 5 degrees between high and low
For example, if P2 is set to 50, the maximum set stop temperature can only be set to 50.
P4: Temperature correction
If there is a deviation between the detected temperature and the actual temperature, this function can be used for calibration. The actual temperature value is equal to the temperature control measurement value plus the calibration value. For example, if the temperature controller detects a temperature of 25.6 ℃ but the actual temperature is 25.8 degrees, P4 can be set to 0.2. The final displayed temperature of the temperature controller is 25.8 (25.8=25.6+0.2).
P5: Delay start
This function is generally used for compressor refrigeration. If you purchase this thermometer for use in a refrigerator cabinet, this value must be set. Depending on the magnitude of the back pressure, it is generally set to 3-6 minutes. If you do not control the compressor or do not need a delay function, skip this option directly.
P6: High temperature alarm
Set the high temperature alarm value. When the temperature exceeds this value, the screen will display an alarm prompt. The high temperature alarm value must be greater than the stop temperature value to be effective.
Special note
1. Pay attention to wiring according to the diagram and do not make mistakes.
2. This document only represents the product knowledge and parameters at the time of editing, and any changes in the future will not be notified separately.
3. K0 and K1 are relay on/off interfaces. Relays act as switches and are passive outputs,Used to control the on/off of load circuits.
4. The display of LLL on the digital tube indicates a sensor malfunction, and the probe wire can be checked for detachment or breakage.
5. The display of HHH on the digital tube indicates that the detected temperature exceeds 110 ℃, and the temperature can be lowered to continue use. If the fault persists, you can check if the probe connection wire is short circuited. Pulling it off and displaying LLL indicates that the motherboard is normal
6. After power failure, press and hold the+- button at the same time before powering on, or press and hold the+- button while working. The digital display will show 888 to restore the factory settings.
Product Size
Product Show
Payment&Transportation
Official Certificate&Certificate
Multiple product supply
Company office environment
Warehouse Real Shot
Standard packaging
We also provide :
Part No | Manufacturer | Date Code | Quantity | Description |
LM22676ADJ | NS | 19+ | 250 | SOP8 |
TPS562201DDCR | TI | 22+ | 795500 | SOT23-6 |
NJG1806K75 | JRC | 22+ | 500000 | DFN6 |
TLV74318PDQNR | TI | 22+ | 402000 | X2SON-4 |
NJG1801K75 | JRC | 22+ | 300000 | SMD |
NJG1804K64 | JRC | 22+ | 300000 | DFN8 |
LM27761DSGR | TI | 22+ | 151000 | WSON8 |
TLV62565DBVR | TI | 22+ | 138000 | SOT23-5 |
TPS613222ADBVR | TI | 22+ | 108000 | SOT23-5 |
LNK625DG-TL | POWER | 22+ | 100000 | SOP-8 |
OPA4322AIPWR | TI | 22+ | 100000 | TSSOP14 |
TLV75528PDRVR | TI | 22+ | 99000 | WSON-6 |
TPS7A2025PDQNR | TI | 22+ | 78500 | X2SON-4 |
TLV62568DBVR | TI | 22+ | 72000 | SOT23-5 |
STM32L051K8U6TR | ST | 22+ | 60000 | QFN32 |
SKY66421-11 | SKYWORKS | 22+ | 56500 | QFN16 |
TPS7A1111PDRVR | TI | 22+ | 54000 | WSON6 |
TLV62569PDDCR | TI | 22+ | 52000 | SOT23-6 |
TLV62569DBVR | TI | 22+ | 48000 | SOT23-5 |
TPS23753APWR | TI | 22+ | 40000 | TSSOP14 |
NB691GG-Z | MPS | 22+ | 30000 | QFN |
SN74AHC1G02DBVR | TI | 22+ | 27939 | SOT-23 |
TPS63000DRCR | TI | 22+ | 23238 | VSON10 |
TLV75533PDRVR | TI | 22+ | 21500 | WSON6 |
NB687BGQ-Z | MPS |